Technical Details

Treated Water Specification | |
---|---|
Max.continuous make-up flowrate |
350 l/h @15ºC |
Distribution flowrate |
1800 l/h @ 3.5 bar |
Conductivity |
<1.3 µS/cm* |
Bacteria |
<100cfu/ml** |
Endotoxin |
<0.25Eu/ml*** |
*subject to a max feedwater conductivity of <700 µS/cm. For use outside the range please contact the technical department. | |
**System to be regularly sanitised and installed according to design guidelines. Sample to be taken from hygienic sample valve and sampled in accordance with VWS guidelines. | |
***Optional ultrafiltration required for endotoxin guarantee. |
Feedwater Requirements | ||
---|---|---|
Hardness |
Total Hardness |
<10* |
Total Chlorine |
CI ppm |
<0.05 |
Silica |
Si02 ppm |
<5 |
Fouling Index |
FI |
<5 |
Iron/Manganese |
FE/Mn ppm |
<0.05 |
Temperature |
Recommended 15-20ºC | |
Max flowrate |
600 l/h | |
Drain requirements (gravity fall with air gap) max during sanitisation |
1800 l/h | |
Feedwater pressure |
10bar (150psi) max 2bar (30psi) min | |
*Requires a softened water feed as standard |
|