Technical Details

Technical Details
Treated Water Specification

Max.continuous make-up flowrate

350 l/h @15ºC

Distribution flowrate

1800 l/h @ 3.5 bar

Conductivity

<1.3 µS/cm*

Bacteria

<100cfu/ml** 

Endotoxin

<0.25Eu/ml***

*subject to a max feedwater conductivity of <700 µS/cm. For use outside the range please contact the technical department.

**System to be regularly sanitised and installed according to design guidelines. Sample to be taken from hygienic sample valve and sampled in accordance with VWS guidelines.

***Optional ultrafiltration required for endotoxin guarantee.

Feedwater Requirements

Hardness

Total Hardness

<10*

Total Chlorine

CI ppm

<0.05

Silica

Si02 ppm

<5

Fouling Index

FI

<5

Iron/Manganese

FE/Mn ppm

<0.05

Temperature

 

Recommended 15-20ºC 

Max flowrate

600 l/h

Drain requirements (gravity fall with air gap) max during sanitisation

1800 l/h

Feedwater pressure

10bar (150psi) max

2bar (30psi) min

*Requires a softened water feed as standard