Technical Details
Treated Water Specification

Model | Biopure 200 | Biopure 300 | Biopure 600 |
---|---|---|---|
Make-up rate |
200 l/h @ 15°C |
300 l/h @ 15°C |
600 l/h @ 15°C |
Delivery flowrate |
30 l/min @ 3.5 bar |
30 l/min @ 3.5 bar |
30 l/min @ 3.5 bar |
Inorganic |
<30 µS/cm* |
<30 µS/cm* |
<30 µS/cm* |
Bacteria |
<1cfu/10ml** |
<1cfu/10ml** |
<1cfu/10ml** |
Endotoxin |
<0.25Eu/ml |
<0.25Eu/ml |
<0.25Eu/ml |
Particles |
<0.05 micron |
<0.05 micron |
<0.05 micron |
* Subject to a maximum feedwater conductivity of <700µS/cm. For use outside this range please contact our technical department
** System to be regularly sanitized and installed following our installation design guidelines. Sample to be taken from hygienic sample valve and sampled in accordance with our guidelines.
Feedwater Requirements
Contaminant (Measure) | Range | Range | Range |
---|---|---|---|
Hardness (Total hardness) (ppm as CaCO3) |
<250 >250* |
<10** >10** |
<10** >10** |
Total Chlorine (CIppm) |
<0.25 |
<0.25 |
<0.25
|
Silica (Sio2ppm) |
<5 |
<5 |
<5 |
Fouling Index (FI) |
<10 |
<10 |
<10 |
Iron/Manganese (Fe/Mn ppm) |
<0.05 |
<0.05 |
<0.05 |
Temperature |
Recommended 15-20°C |
Recommended 15-20°C |
Recommended 15-20°C |
Flowrate |
20 l/min |
20 l/min |
20 l/min |
Drain requirements Gravity fall with air gap, max during sanitization |
45 l/min |
45 l/min |
45 l/min |
Feedwater Pressure |
10bar (150psi) max 2 bar (30psi) min |
10bar (150psi) max 2 bar (30psi) min |
10bar (150psi) max 2 bar (30psi) min
|
* Requires a softened water feed or an increase in the frequency of RO acid cleaning
** Requires a softened water feed as standard
Weights, Dimensions and installations
Height |
1820mm (71.7") |
1820mm (71.7") |
1820mm (71.7") |
Width |
730mm (28.75") |
730mm (28.75") |
756mm (29.76") |
Depth |
890mm (35") |
890mm (35") |
1100mm (43.31") |
Supply Weight |
180kg (396lb) |
180kg (396lb) |
210kg (463lb) |
Operational Weight |
530kg (1,168lb) |
530kg (1,168lb) |
560kg (1,235lb) |
Installation |
Floor mounted |
Floor mounted |
Floor mounted |
Electrical Requirements
Mains input |
230V ac, 50Hz |
230V ac, 50Hz |
230V ac, 50Hz |
Systems control voltage (not including pumps and UV) |
24V dc |
24V dc |
24V dc |
Power consumption (peak demand) |
2200VA |
2200VA |
2200VA |
Electrical protection rating |
20amps |
20amps |
20amps |
Noise level during recirculation |
<60dBA |
<60dBA |
<60dBA |